VICTRON PWM CHARGE CONTROLLER LCD & USB
Victron pwm charge controller 12/24V & 48V:
■ Liquid crystal display: for status monitoring and set-up
■ Load output: over-discharge of the battery can be prevented by connecting all loads to the load output.
The load output will disconnect the load when the battery has been discharged to a pre-set voltage.
Some loads (especially inverters) can best be connected directly to the battery, and the inverter remote control connected to the load output.
A special interface cable may be needed, please see the manual. The connect and disconnect voltages are adjustable.
■ Day/night timing of the load output: this option allows for a pre-set ON-time after dusk.
■ Programmable battery charge algorithm: preprogrammed algorithms for AGM, GEL, Flooded or LiFePO4 batteries (with internal BMS only)
■ Two 5 Volt USB outputs: maximum current (both outputs combined) 2A
| Label | Value |
|---|---|
| Self-consumption | <10mA |
| Load output | Manual control + low voltage disconnect +timer (DUO version: 2 ports USB 5V/2A) |
| Overload protection | Shut down after 60 s in case of 130% load |
| Overload protection | Shut down after 5 s in case of 160% load |
| Overload protection | Short circuit: immediate shut down |
| Humidity | Max 95% (non-condensing) |
BLUESOLAR PWM CHARGE CONTROLLER-LCD & USB 12/24V & 48V
| MODEL |
12/24-5 |
12/24-10 |
12/24-20 |
12/24-20 |
12/24-30 |
48-10 |
48/20 |
48/30 |
|---|---|---|---|---|---|---|---|---|
|
SKU |
23676S |
22976Z |
22979F |
23709E |
22980P |
23131W |
23682L |
23683N |
|
Battery Voltage |
12/24V with automatic system voltage detection |
12/24V with automatic system voltage detection |
12/24V with automatic system voltage detection |
12/24V with automatic system voltage detection |
12/24V with automatic system voltage detection |
48V |
48V |
48V |
|
Rated charge current |
5A |
10A |
20A |
20A |
30A |
10A |
20A |
30A |
|
Automatic |
Yes |
Yes |
Yes |
10,5V/21V |
Yes |
Yes |
Yes |
Yes |
|
Max PV voltage |
28V / 55V |
28V / 55V |
28V / 55V |
28V / 55V |
28V / 55V |
100V |
100V |
100V |
|
Protection |
Battery reverse polarity (fuse) |
Battery reverse polarity (fuse) |
Battery reverse polarity (fuse) |
Battery reverse polarity (fuse) |
Battery reverse polarity (fuse) |
Battery reverse polarity (fuse) |
Battery reverse polarity (fuse) |
Battery reverse polarity (fuse) |
|
Grounding |
Common positive |
Common positive |
Common positive |
Common negative |
Common positive |
Common positive |
Common positive |
Common positive |
|
Operating |
-35 a +60°C (full load) |
-35 a +60°C (full load) |
-35 a +60°C (full load) |
-35 a +55°C |
-35 a +60°C (full load) |
-35 a +60°C (full load) |
-35 a +60°C (full load) |
-35 a +60°C (full load) |
|
Dimensions |
96x169x36 |
96x169x36 |
96x169x36 |
101x184x47 |
101x184x47 |
101x184x47 |
101x184x47 |
101x184x47 |
|
Weight kg (lbs) |
0,15 (0.33) |
0,15 (0.33) |
0,15 (0.33) |
0,3 (0.7) |
0,3 (0.7) |
0,3 (0.7) |
0,3 (0.7) |
0,3 (0.7) |
No data found.




